| Product |
Description |
Application |
| FSK-7150A |
Foil: 7u / Polyethylene / 3-Way Scrim 8x12/100mm / Kraft: 50gsm |
Commercial grade FSK Facing for duct wrap in HVAC system. Used for HVAC engineering that fire rating is not rigorous. |
| FSK-7150B |
Foil: 7u / Polyethylene /Two-Way Scrim 12.5x12.5mm / Kraft: 50gsm |
| FSK-7160A |
Foil: 7u / Polyethylene /3-Way Scrim 8x12/100mm /Kraft: 60gsm |
Thicker Kraft raises mechanical Economic grade FSK Facing for duct wrap in HVAC system. Used for HVAC engineering that fire rating is not rigorous. |
| FSK-7160B |
Foil: 7u / Polyethylene /Two-Way Scrim 12.5x12.5mm / Kraft: 60gsm |
| FSK-7350B |
Foil: 7u / Polyethylene / Two-Way Scrim 6.25x12.5 /Kraft: 50gsm |
Closer scrim and thicker Kraft makes facing stiff and neat. Economic grade FSK Facing for duct wrap in HVAC system. Used for HVAC engineering that fire rating is not rigorous. |
| FSK-7360B |
Foil: 7u / Polyethylene / Two-Way Scrim 6.25x12.5 /Kraft: 60gsm |
| FSK-R7150A |
Foil: 7u / Flame Retardant Adhesive / 3-Way Fiberglass Scrim 8x12/100mm/Kraft: 50gsm |
Vapor barrier for duct wrap in HVAC system. Meet the requirement of rigorous fire rating. |
| FSK-R7150B |
Foil: 7u / Flame Retardant Adhesive / Two-Way Fiberglass Scrim 12.5x12.5mm /Kraft: 50gsm |
| FSK-R7160A |
Foil: 7u / Flame Retardant Adhesive / 3-Way Fiberglass Scrim 8x12/100mm /Kraft: 60gsm |
Thicker Kraft increases the mechanical strength of facing. Vapor barrier for duct wrap in HVAC system. Meet the requirement of rigorous fire rating. |
| FSK-R7160B |
Foil: 7u / Flame Retardant Adhesive / Two-Way Fiberglass Scrim 12.5x12.5mm/Kraft: 60gsm |
| FSK-R7350B |
Foil: 7u / Flame Retardant Adhesive / Two-Way Fiberglass Scrim 6.25x12.5mm/Kraft: 50gsm |
Closer scrim makes facing stiff and neat. Vapor barrier for duct wrap in HVAC system. Meet the requirement of rigorous fire rating. |
| FSK-R7360B |
Foil: 7u / Flame Retardant Adhesive / Two-Way Fiberglass Scrim 6.25x12.5mm /Kraft: 60gsm |
Closer scrim and thicker Kraft makes facing stiff and neat, and provides higher mechanical strength. Vapor barrier for duct wrap in HVAC system. Meet the requirement of rigorous fire rating. |
| FK-750 |
Foil: 7u /Polyethylene /Kraft: 50gsm |
Low cost vapor barrier of duct wrap in HVAC system. Used for HVAC engineering that both fire rating and tear-resistance are not rigorous. |
| FK-760 |
Foil: 7u /Polyethylene / Kraft: 60gsm |
Low cost vapor barrier of duct wrap in HVAC system but with thicker Kraft. Used for HVAC engineering that both fire rating and tear-resistance are not rigorous. |